/* * Copyright Amazon.com, Inc. or its affiliates. All Rights Reserved. * * Licensed under the Apache License, Version 2.0 (the "License"). * You may not use this file except in compliance with the License. * A copy of the License is located at * * http://aws.amazon.com/apache2.0 * * or in the "license" file accompanying this file. This file is distributed * on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either * express or implied. See the License for the specific language governing * permissions and limitations under the License. */ /* * Do not modify this file. This file is generated from the kendra-2019-02-03.normal.json service model. */ using System; using System.Collections.Generic; using System.Xml.Serialization; using System.Text; using System.IO; using System.Net; using Amazon.Runtime; using Amazon.Runtime.Internal; namespace Amazon.Kendra.Model { /// /// Provides information about a data source synchronization job. /// public partial class DataSourceSyncJob { private string _dataSourceErrorCode; private DateTime? _endTime; private ErrorCode _errorCode; private string _errorMessage; private string _executionId; private DataSourceSyncJobMetrics _metrics; private DateTime? _startTime; private DataSourceSyncJobStatus _status; /// /// Gets and sets the property DataSourceErrorCode. /// /// If the reason that the synchronization failed is due to an error with the underlying /// data source, this field contains a code that identifies the error. /// /// [AWSProperty(Min=1, Max=2048)] public string DataSourceErrorCode { get { return this._dataSourceErrorCode; } set { this._dataSourceErrorCode = value; } } // Check to see if DataSourceErrorCode property is set internal bool IsSetDataSourceErrorCode() { return this._dataSourceErrorCode != null; } /// /// Gets and sets the property EndTime. /// /// The Unix timestamp when the synchronization job completed. /// /// public DateTime EndTime { get { return this._endTime.GetValueOrDefault(); } set { this._endTime = value; } } // Check to see if EndTime property is set internal bool IsSetEndTime() { return this._endTime.HasValue; } /// /// Gets and sets the property ErrorCode. /// /// If the Status field is set to FAILED, the ErrorCode /// field indicates the reason the synchronization failed. /// /// public ErrorCode ErrorCode { get { return this._errorCode; } set { this._errorCode = value; } } // Check to see if ErrorCode property is set internal bool IsSetErrorCode() { return this._errorCode != null; } /// /// Gets and sets the property ErrorMessage. /// /// If the Status field is set to ERROR, the ErrorMessage /// field contains a description of the error that caused the synchronization to fail. /// /// [AWSProperty(Min=1, Max=2048)] public string ErrorMessage { get { return this._errorMessage; } set { this._errorMessage = value; } } // Check to see if ErrorMessage property is set internal bool IsSetErrorMessage() { return this._errorMessage != null; } /// /// Gets and sets the property ExecutionId. /// /// A identifier for the synchronization job. /// /// [AWSProperty(Min=1, Max=2048)] public string ExecutionId { get { return this._executionId; } set { this._executionId = value; } } // Check to see if ExecutionId property is set internal bool IsSetExecutionId() { return this._executionId != null; } /// /// Gets and sets the property Metrics. /// /// Maps a batch delete document request to a specific data source sync job. This is optional /// and should only be supplied when documents are deleted by a data source connector. /// /// public DataSourceSyncJobMetrics Metrics { get { return this._metrics; } set { this._metrics = value; } } // Check to see if Metrics property is set internal bool IsSetMetrics() { return this._metrics != null; } /// /// Gets and sets the property StartTime. /// /// The Unix timestamp when the synchronization job started. /// /// public DateTime StartTime { get { return this._startTime.GetValueOrDefault(); } set { this._startTime = value; } } // Check to see if StartTime property is set internal bool IsSetStartTime() { return this._startTime.HasValue; } /// /// Gets and sets the property Status. /// /// The execution status of the synchronization job. When the Status field /// is set to SUCCEEDED, the synchronization job is done. If the status code /// is set to FAILED, the ErrorCode and ErrorMessage /// fields give you the reason for the failure. /// /// public DataSourceSyncJobStatus Status { get { return this._status; } set { this._status = value; } } // Check to see if Status property is set internal bool IsSetStatus() { return this._status != null; } } }